The Run Control can be activated by clicking on the Run Control.
The following series of steps must be performed to start data acquistion
using the Run Control. Figure 4.5 shows the RunControl window.
Figure 4.5:
The RunControl window.
| 6.0in][c]6in
|
- CONNECT. Click once on the Connect button to connect
to the SBC. This may take few moments, please be patient.
- CONFIGURE. Once connected, the Configure button will
be available. Click once on this button to configure the SBC into
a desired RoC. Select the RunType (test_roc1) and click OK on the
pop-up window. Now your SBC is ready to accept instructions as
a RoC
- DOWNLOAD. Click this button once to download the CRL codes into the
RoC. A successful download is indicated by INFO message in the run
control window and is followed by the appearence of the PreStart button.
- PRESTART. Click this button to perform the PreStart transition.
Actions outlined in the Prestart transition in the CRL will be
performed. A successful PreStart transition will be indicated in the
EB window by a message '-Got all fragments of prestart'. The Go
button will also appear at the end of a successful PreStart.
- GO. To start data acquistion, click once on the Go
button. After a successful Go, the event and data rates are displayed
in various fields as well as on a graph. To end the run, press the End
key once. To Start the next run, go through the PreStart and Go sequence
again.
To gracefully exit from the CODA Master, use the Kill All button, and
exit from the Config menu.